How loud is a heat pump, really?

Modern air source heat pumps typically produce around 40-60 dB at close range. For context, that's roughly in the territory of a quiet conversation or a domestic fridge. Most owners report noticing it for the first few weeks and then largely tuning it out.

The sound comes from two places: the compressor and the fan. You'll hear it more when the unit is working hardest — very cold days, and during defrost cycles.

Normal, not a fault In cold weather your unit will periodically run a defrost cycle, melting ice off the heat exchanger. It typically lasts 5-10 minutes and can produce visible steam and a change in sound. This is designed behaviour, not a problem.

Sizing matters more than the badge on the unit

A heat pump that's the wrong size for the home is noisier in practice than one that's correctly sized, regardless of the manufacturer's quoted figures:

A correctly sized unit running steadily at a low flow temperature is the quietest outcome — which is why the room-by-room heat loss calculation matters for noise, not just for efficiency and radiator sizing.

Do you need planning permission?

For most homes, no. Air source heat pumps generally fall under permitted development, meaning no planning application is needed provided conditions are met. England's rules were significantly relaxed in 2025:

You will still need permission if…

The noise condition — and an honest caveat

Permitted development depends on passing a calculation under MCS 020, the planning standard that estimates your unit's sound level at a neighbour's habitable room window. Your MCS-certified installer carries out this calculation — it's their responsibility, not yours.

Sources disagree on the current figure Published guidance during 2026 is genuinely inconsistent on the exact limit. Several sources cite 42 dB(A), while others state the limit tightened to 37 dB(A) from 28 May 2026, alongside MCS 020 becoming the only accepted certification route. We're not able to state definitively which applies to your installation — confirm the current figure directly with your MCS-certified installer or the Planning Portal before relying on either number.

Rules differ across the UK

NationPosition
EnglandMost permissive — 1-metre boundary rule removed (2025), 1.5m³ size cap on houses, up to two units on detached homes
WalesStricter — reported 3-metre boundary clearance, 1m³ size cap, one unit per property
Scotland & Northern IrelandBroadly similar to England's pre-2025 rules, including a 1-metre boundary requirement

Devolved planning rules change independently of England's. Always confirm current requirements for your nation before proceeding.

If the calculation doesn't pass

A failing result usually isn't the end of the project. Common fixes:

Get this sorted before booking Failing the noise calculation can affect both permitted development status and your grant eligibility, since the Boiler Upgrade Scheme requires an MCS-certified installation. Ask for the siting survey and noise calculation to be done before you commit to a date.

The noise calculation and siting survey are part of what an MCS-certified installer does as standard.